Elcon Gaz

WATER – Dewhot have found that the biggest effect on their range of gas geysers and the way they operate is water, due to the following factors:
FLOW RATE – This is the biggest of the two and is why Dewhot have so many different sized units in the diaphragm activated range. The diaphragm activated range have an operating flow rate of their maximum down to half (which is true for all the sizes)
The flow rate in litres/minute is needed to size a geyser correctly so that the you the customer will get the hot water temperature and volume that you are expecting .
To determine the flow rate one must do a “Bucket Test”
BUCKET TEST – Use a bucket of known size and then run the COLD water tap of the shower, bath or basin (wherever the hot water will be needed), it must be the cold water as the hot water may be plumbed through an existing pressurised geyser and cold water is what will be connected to the future gas geyser. Run the cold water at the flow rate that you would normally use it at, catch the water in the bucket for a timed minute and then measure how may litres you have in the bucket.
This information gives you a flow rate of X litres/minute. You can now use this information to determine the size of the gas geyser needed for the outlet by selecting the next size geyser up from this figure and you will have the right geyser for your pipes, water pressure, personal preferences and shower head.


Domestic constant temperature unit with natural exhaust
Automatic water flow/gas linked ignition, automatic pulse ignition from one “D” cell torch battery
Aluminium coated front panel
LCD control panel to set desired water temperature
Automatic flame height/water flow control
Constant temperature with varying water flow
Can mix with cold water
Water pressure 0.3 – 5 bar
For outdoor use (under cover)
(additional cover recommended) – Type D

Operates from one-meter to a fifty-meter head of water pressure
Can be mounted indoors or out
Needs a flue
Flow range from 12lt to 3lts/min
Flow control tap on cold water supply
Allows addition of cold water
Water flow sensor, no diaphragm to freeze
Automatic start, runs on two torch batteries
Has adjustable pressure relief valve/drain stem
Anti-corrosive aluminium coated
For outdoor (under cover) or indoor use – Type B

White baked enamel front panel
Instant water heater with natural exhaust
Can be used indoors without a flue
Oxygen Depletion Sensor (ODS)
Flow from 5lt – 1lt/min
Allow for added cold water
Water flow sensor (no diaphragm)
Automatic ignition from two standard torch batteries
Single gas control knob
Cold water inlet control valve
Water pressure 0.1 bar – 5 bar (one-meter to fifty-meter head of water)
Adjustable pressure relief valve
For indoor & outdoor (undercover) use (no flue) – Type A

Instant water heater with natural exhaust
Water gas linked automatic ignition, automatic pulse ignition from two “D” cell torch batteries
No pilot light
Stainless steel front panel
LCD temperature guage
Flame height, gas flow knob
Temperature, water flow knob
On & off switch for cold or hot water
Water pressure 0.3 – 5 bar
Starting indicator light
For outdoor use only (under cover) – Type D

Domestic instant water heater with natural exhaust
Water gas linked automatic ignition, automatic pulse ignition from two standard torch batteries
White enamel front and back
LCD temperature guage
Flame height, gas flow knob
Temperature, water flow knob
Water pressure 0,3 – 5,0 bar
Water pressure stabilizing design
For outdoor use only (under cover) – Type D
Please click on the link below to calculate the gas consumption of your selected gas geyser. By simply selecting your geyser size and intended usage time, you will be able see the running costs of your unit. Note: if you know the price/kg of LPG then you can adjust this, otherwise it will default to the average rate calculated.
PLEASE NOTE: This consumption tool is calculated on maximum consumption which is at a temp of around 65 degrees, to give you an indication, a shower is generally set at 40/41 degrees. The tool is a guideline and not an exact estimation, as there are variables.
We hope you find this useful and any constructive feedback on the use of this tool would be much appreciated.
Works with Google Chrome!


Extra Large Cover - (16lt EcoDwe/16lt CT)
Large Cover – (8,12lt EcoDew/16lt S/Steel/12lt LP,CT)
Medium Cover – (6,8,10,12 S/Steel)
Small Cover – (5lt LP)

90mm Flue (6lt)
110mm Flue (8-12lt)
128mm Flue (16lt)


Dimensions: 310mm X 510mm
Cut-out: 270mm X 470mm

Dimensions: 300mm X 510mm
Cut-out: 270mm X 475mm

Dimensions: 300mm X 510mm
Cut-out: 270mm X 475mm
- Brushed Stainless Steel
- Glass Top
- Cast Iron Pot Rests
- Electric Ignition
- Flame-Failure Safety Valves

Dimensions: 575mm X 495mm
Cut-out: 550mm X 470mm

Dimensions: 575mm X 495mm
Cut-out: 550mm X 470mm

Dimensions: 600mm X 510mm
Cut-out: 550mm X 480mm

Dimensions: 580mm X 510mm
Cut-out: 550mm X 480mm

Dimensions: 855mm X 490mm
Cut-out: 830mm X 470mm
- Brushed Stainless Steel
- Glass Top
- Cast Iron Pot Rests
- Electric Ignition
- Flame-Failure Safety Valves

Dimensions: 860mm X 495mm
Cut-out: 830mm X 470mm

Dimensions: 860mm X 495mm
Cut-out: 830mm X 470mm

Dimensions: 870mm X 510mm
Cut-out: 830mm X 470mm

Dimensions: 865mm X 510mm
Cut-out: 830mm X 470mm

Dimensions: 860mm X 500mm
Cut-out: 830mm X 470mm